How to Determine if an EIESD Ionizing Bar is Operating Normally


Introduction


Ionizing bars (or ionizing air bars) are used to neutralize static electricity by generating positive and negative ions.

Even if the bar is powered, it may not produce sufficient ions, leading to residual static.


Proper testing ensures:


Effective static elimination


Balanced ion output


Safety and longevity of the equipment


1. Visual Inspection


Before using instruments, perform a physical check:


Power indicator LED: Most ionizers have an LED showing that the unit is energized.


Emitter pins: Check for dust, oil, or dirt buildup. Contaminated pins reduce ion output.


Cables and connectors: Look for cracks, loose connections, or signs of arcing.


Mounting and alignment: Ensure the bar hasn’t shifted and points toward the target surface.


⚠️ Even if everything looks fine, the bar might still underperform — so measurement is essential.


2. Measure Static Decay Time

What It Is:


Static decay time measures how long it takes for a charged surface to neutralize when exposed to the ionizer.


Short decay time indicates strong ion output; long decay time indicates weak or malfunctioning ionization.


How to Measure:


Charge a test surface (plastic sheet, film, or PCB) to a known voltage (e.g., 1000–2000 V).


Position the surface at the normal operating distance from the ion bar.


Turn on the ionizer and measure voltage over time with an electrostatic voltmeter.


Typical Values:


Good condition: Decay to ±100 V in 2–5 seconds for plastics or films.


Problem: Decay takes longer than 10 seconds → check bar alignment, distance, or emitter condition.


3. Check Ion Balance


Positive and negative ions should be balanced to prevent residual charges.


Use an ion balance meter (or dual-polarity voltmeter).


Procedure:


Place the meter at the normal operating distance.


Turn on the ionizer and read the balance (positive vs negative voltage).


Acceptable range: ±10 V for most industrial applications.


If the reading is outside this range, it may indicate emitter wear, contamination, or power supply issues.


4. Observe Target Surface Behavior


Before ionization: Charged surfaces attract dust or cling to other materials.


After turning on the bar: Dust attraction should reduce immediately and surface should become neutral.


If dust continues to cling, or the material still sticks due to static, the bar may be underperforming.


5. Listen and Smell for Abnormal Signs


Audible buzzing or sparking: Minor corona noise is normal, but loud continuous arcing is a problem.


Ozone smell: Some odor is expected with AC ionizers, but strong ozone indicates over-voltage or malfunction.


6. Check Power Supply and Grounding


Ensure the power supply is operating correctly:


Correct input voltage


Power LED indicators on


HV output normal (if visible on the device)


Confirm that ground wires are secure. A disconnected ground can reduce ion output and cause imbalance.


7. Periodic Maintenance Checks


Even if the bar is working, regular checks improve reliability:


Clean emitter pins (weekly or monthly, depending on environment).


Inspect HV cables and connectors.


Measure static decay and ion balance quarterly.


Replace worn or damaged bars per manufacturer recommendations.


8. Summary Table

Check Method Normal Condition Problem Indication

Power LED On Off → check power supply

Emitter pins Clean, intact Dirty, bent, broken

Static decay 2–5 s to ±100 V >10 s → weak ion output

Ion balance ±10 V Outside ±10 V → imbalance

Dust / clinging Minimal Persistent attraction → ineffective

Noise / ozone Mild Loud buzzing / strong smell → HV issue

9. Conclusion


To ensure an ionizing bar is functioning normally:


Inspect visually for physical damage or contamination.


Measure static decay time for effectiveness.


Check ion balance to ensure equal positive and negative ions.


Observe surface behavior and dust attraction.


Verify power supply and grounding.


A combination of visual, electrical, and functional checks is the most reliable way to confirm proper operation.


Table of Content list
Decent Static Eliminator: The Silent Partner in Your Quest for Efficiency!

Quick Links

About Us

Support

Contact Us

  Telephone: +86-188-1858-1515
  Phone: +86-769-8100-2944
  WhatsApp: +8613549287819
  Email: Sense@decent-inc.com
  Address: No. 06, Xinxing Mid-road, Liujia, Hengli, Dongguan, Guangdong
Copyright © 2025 GD Decent Industry Co., Ltd. All Rights Reserved.