Product Overview

The inductive ion air snake removes static electricity and dust from hard-to-reach or hard-to-contact objects. Its flexible gooseneck tube can be bent freely to aim the air nozzle at target positions, allowing ion airflow to blow directly onto workpiece surfaces without manual operation.

Product Features

  1. Compact, delicate and easy to move; multi-directional flexible tube design, suitable for static elimination in various working scenarios.

  2. Fast static neutralization; ion balance voltage: 0V±10V, airflow speed continuously adjustable.

  3. Built-in high-voltage power supply for stable operation.

  4. Alloy body with rigid structure, low maintenance cost and long service life.

  5. Sensor-triggered air blowing to reduce compressed air consumption.

  6. Replaceable ion needle for convenient maintenance.

  7. Compatible with optional foot switch.

    image.png

Main Applications

Precision electronic manufacturing, electronic assembly lines, microelectronics production, optoelectronics industry; pharmaceutical assembly lines, printing & packaging; molding of tiny parts, plastic film slitting, ring winding & film lamination, mold demolding and other processes.

Dimension Description

  • Metal gooseneck tube length: 490 mm

  • Air nozzle section length: 58 mm

  • Overall total length: 548 mm

  • Base dimensions: 158 mm (length) × 100 mm (height)

  • Adjustable air inlet fitting

Basic Technical Parameters

Item

Parameter

Operating Voltage

4.0KV

Current Consumption

200μA

Operating Temperature Range

0℃ ~ 50℃

Length of Gooseneck Hose

400mm

Net Weight

2.5kg

Power Cord Length

1.5 meters

Compressed Air Pressure

40–70 psi

Operating Air Velocity

>10m/sec

Static Decay Test Conditions

Unified test environment: Operating Voltage: 4.6kV; Test Voltage: 1kV down to 100V; Ambient Temperature: 22℃

Test Distance

30mm

90mm

150mm

Decay Time (Positive Charge)

0.1s

0.2s

0.9s

Decay Time (Negative Charge)

0.1s

0.2s

0.7s

Offset Residual Voltage (Positive Charge)

-2V

-3V

+9V

Offset Residual Voltage (Negative Charge)

-1.3V

-3.6V

+9.1V

Remarks

  1. All test data are measured by ME268A static tester.

  2. Test results may fluctuate depending on ambient conditions, air quality, temperature and humidity.

Previous: 
Next: 

Related Products

content is empty!

Decent Static Eliminator: The Silent Partner in Your Quest for Efficiency!

Quick Links

About Us

Support

Contact Us

  Telephone: +86-188-1858-1515
  Phone: +86-769-8100-2944
  WhatsApp: +8613549287819
  Email: Sense@decent-inc.com
  Address: No. 06, Xinxing Mid-road, Liujia, Hengli, Dongguan, Guangdong
Copyright © 2025 GD Decent Industry Co., Ltd. All Rights Reserved.